  • Highest measuring precision
  • Measuring of optical rotatory dispersion (ORD)
  • Up to 5 wavelengths
  • Calibration free because of spectral lamps
Spectral multi-wavelength polarimeter

NEW – High resolution of 0.0001° !

The high-resolution (0.0001 °) polarimeter H532 with up to 5 wavelengths and the highest precision!

The technology of the Polartronic H532, which is securely packaged under the elegant housing, works with a further developed software, which is known from the ATR series refractometer, with a large programmable display. The input of  the following is possible: sample identification numbers, statistical evaluation in the case of multiple measurements and protocols to be defined by the user for output via a printer or PC, individually adjustable for each of the 10 available methods.

Polarimeters of the Polartronic H series are automatic, high-resolution measuring instruments with the following characteristics:

 

  • Accurate measurement of the optical activity of liquids according to ICUMSA, O.I.M.L. And Australian Standard K 157, European and American Pharmacopoeia
  • For the highest demands in quality and research laboratories
  • High precision over the entire measuring range by direct measurement of the angle
  • Short measuring times, no mechanical wear
  • Suitable for microtubes
  • Can be used for various applications with 5 wavelengths; Standard wavelengths are: 365nm, 435nm, 546nm, 579nm and 589nm (others on request)
  • Automatic temperature correction when using a corresponding tube
  • Calibration-free by spectral lamps
  • Safe and documented results through fully automatic and digital, objective and fast measurement
  • 10 methods and 10 scales programmable
  • Continuous measurement without START and RESET
  • Display of optical density
  • Determination of the optical rotatory dispersion (ORD), measurement at several wavelengths
  • RS232 to Ethernet adapter for data transfer to the PC
  • Extensive control software for test routines and configuration of the device
  • GLP / GMP compliant documentation
  • 21 CFR part 11 ready, corresponding software “Aquisys 2008” optionally available
  • Robust metal housing
  • High quality “Made in Germany” as well as advice and service on site possible
  • Internal measured value memory for 999 values

The polarimeters of the Polartonic H series meet all requirements according to 21 CFR Part 11 with a corresponding software (AQUISYS 2008). AQUISYS 2008 is a software fully compliant to 21 CFR Part 11 for SCHMIDT + HAENSCH Polarimeter:

AQUISYS 2008 Übersicht

AQUISYS 2008 UniPol

 

  • Audit Trail function (history logging)
  • Report generation
  • Electronic signature
  • Encrypted, electronic data storage and archiving
  • Data transfer to spreadsheet applications
  • Remote-mode

Wavelength-Matrix Polartronic M/H-Series

specifications

Main specifications

Measurement scales °Optical rotation, °Specific rotation, °Z International Sugar Scale, % Concentration (g/mL, g/100mL, g/L)
7 scales freely
Measuring range ±89° (4 quadrants)
Resolution 0.0001° / 0.01°Z
Precision 0.002° / ± 0.01°Z
Reproducibility 0.001° / ± 0.01°Z
Sensitivity Up to OD 3
Wavelength Up to 5 wavelengths fixed: 365, 435, 546, 578, 589 (others on request)
Response time ≤ 4 sec. over the entire measuring range

Temperature

Temperature measurement If temperature sensor with appropriate tubes is used / T-Cell Peltier tubes
Temperature sample control with appropriate tubes via external water bath / Peltier temperature controlled sample tubes
Temperature control range depends on the water bath / 18 - 40 °C
Temperature resolution depends on the water bath / 0.01 °C
Temperature precision depends on the water bath / ± 0.03 °C
Temperature reproducibility depends on the water bath / 0.05 °C

Additional information

Light source Spectral lamps, calibration free
Display LCD display, monochrom
Operation Alpha numerical keybord, 16 x 16 characters
Operation TOUCH version Alpha numerical keyboard
Interface / Communication 2x RS232, 1x parallel, 1 PS2, USB (adapter)

Conformity

Conformity nternational Pharmacopoeia, OIML, ASTM, ICUMSA, Australian Standard K157

Do you have questions about this product?

Get in touch with us.

Related products

Dear valued customer and business friend,

We are taking all possible measures to secure the health of our employees as well as our customers.

As we have already informed you, Schmidt+Haensch remains fully operational.

We are organising whenever possible work from home offices. Our production lines are continuously producing and our supply chains are so far secured.

We are most interested to offer our services as usual. Instead of personal visits we have built up internet communications in order to help you remotely.

All our contacts as well as phone numbers remain accessible.

For service issues please do not hesitate to contact us via e-mail to service@schmidt-haensch.de or telephone under +49 (030) 417 072 – 41 / - 42

For sales inquiries please contact us via e-mail to sales@schmidt-haensch.de or call our sales engineers.

We wish you to stay well and healthy.

Let us try to overcome these most exceptional circumstances by looking after each other with the necessary care and distance.

Best regards

Mathis Kuchejda

-President-

Corona Update