15761

Certified reference material for refractometers

Calibration of refractometers at 589 nm

Refractive index standards by SCHMIDT + HAENSCH with high precision over the whole temperature and wavelength range. The reference liquids are traceable to PTB standards and allow for high-quality verification, calibrating or testing of your refractometer. You can find more information at “Specifications”, and you are welcome to contact us to request more reference materials.

 

Checkpoints

  • Customized reference material available
  • Verification of the refractive index for refractometers
  • Factory certified reference materials
  • Valid for large temperature and wavelength ranges
  • Refractive index samples with high precision

 

ID-N° in specifications below 

Specifications

NameRefractive indexTemperature rangeCertificateTolerance of RIID-N°
CRM-R 29 B20 °C ≈ 1.28920 °C and 25 °CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15761
CRM-R 29 P20 °C ≈ 1.2895 °C to 95 °CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15762
CRM-R 33 B20 °C ≈ 1.33320 °C and 25 °CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15714
CRM-R 33 P20 °C ≈ 1.3335 °C to 95°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
13635
CRM-R 37 B20 °C ≈ 1.37720 °C and 25 °CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15715
CRM-R 37 P20°C ≈ 1.3775 °C to 95°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
14659
CRM-40 B20°C ≈ 1.40420°C and 25°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
06491
CRM-40 P20°C ≈ 1.4045 to 95°CPTB certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
14658
CRM-46 B20°C ≈ 1.44620°C and 25°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15717
CRM-46 P20°C ≈ 1.4465 to 95°CPTB certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
14521
CRM-47 B20°C ≈ 1.47420°C and 25°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
01892
CRM-47 P20°C ≈ 1.4745 to 95°CPTB certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
14522
CRM-50 B20°C ≈ 1.50620°C and 25°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
15718
CRM-50 P20°C ≈ 1.5065 to 95°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
13756
CRM-65 B20°C ≈ 1.65820°C and 25°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
07206
CRM-65 P20°C ≈ 1.6585 to 95°CFactory certificateat 20 °C dnD=0.00001
other temperature: dn=0.00005
13760
CRM-R Customcustomized 10 ml reference material for RI in the range 1.36 bis 1.70 RI, calibrated to dn=0.00005 accuracy; with factory certificate01891

Do you have any questions about this product?

Get in touch with us

Services Request